[QFJ-725] Note that sequence numbers will be reset at 'StartTime' even if ResetOnLogon=N Created: 27/Dec/12  Updated: 12/Apr/13

Status: Open
Project: QuickFIX/J
Component/s: Documentation
Affects Version/s: None
Fix Version/s: None

Type: New Feature Priority: Default
Reporter: Jim Mulcahey Assignee: Unassigned
Resolution: Unresolved Votes: 0
Labels: QuickfixJ


 Description   

When a new session is started based on the QF/J 'StartTime' configuration setting, the sequence numbers will be reset even if ResetOnLogon=N. The Configuration section in the User Manual does not make this clear, as 'StartTime' is only defined as..

"Time of day that this FIX session becomes activated"

It would help to have a note added in the Configuration section that the sequence numbers will be reset even if ResetOnLogon=N.



 Comments   
Comment by Jörg Thönnes [ 12/Apr/13 ]

A new FIX session is defined by resetting the numbers to 1. Or in other words: You cannot start a new session
without setting numbers back to 1.

The ResetOnLogon forces to reset the sequence numbers even if we are in the normal [StartTime, EndTime] frame.

So "Time of day that this FIX session becomes activated" should get "Time of day when the new FIX session starts".

Actually, the new FIX session starts some where in between the previous days EndTime and the todays StartTime.
And the engine really resets the sequence numbers if it detects that it is out of session time (e.g. after last days EndTime).

Comment by Jim Mulcahey [ 12/Apr/13 ]

Thanks for the clarification, Jörg. You can go ahead and close this ticket.

Generated at Sat Nov 23 09:16:41 UTC 2024 using JIRA 7.5.2#75007-sha1:9f5725bb824792b3230a5d8716f0c13e296a3cae.