Uploaded image for project: 'QuickFIX/J'
  1. QuickFIX/J
  2. QFJ-195

For an initiator to CME, fromAdmin() callback is not activated for seq-num too low on logon

    Details

    • Type: Other
    • Status: Closed
    • Priority: Default
    • Resolution: Fixed
    • Affects Version/s: 1.1.0
    • Fix Version/s: None
    • Component/s: Engine
    • Labels:
      None

      Description

      Hello,

      i tested my fixengine by creating an acceptor and an initiator session on the same machine. the initiator is configured to login to the acceptor session. They had different sequence numbers, so the logout() callback from initiator session is getting called. But the fromAdmin() callback is never activated. That´s confusing, because when initiating a session to an remote fix engine this works, I use to catch the fromAdmin() callback and reset the sequencenumbers by reading the remote message sequencenumber; internally it does not work. Why ?.

      Regards
      Thomas Hügel

        Attachments

          Activity

            People

            • Assignee:
              admin Steve Bate
              Reporter:
              scramsay stacey ramsay
            • Votes:
              0 Vote for this issue
              Watchers:
              0 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: